Build: #2 was successful
Job: Test Tools macOS 15 Py3.12 was successful
Code commits
CASA6
-
Srikrishna Sekhar 6bf9a287644247a534350fc7b2eaa493d427eb54 m
CAS-14874 : Fix for nproc dependent beam size
The reported issue on the ticket was caused by an incorrect cache
refresh of the number of channels in an SPW.
If there are N input MSs, if the N-1 SPW has more channels than the Nth
SPW for the same SPW row, the delta in the number of channels is filled
with zeros that leads to an incorrect Briggs weighting calculation.
The fix was to correctly update the SPW channel count per MS, regardless
of which MS we are currently processing internally. Previously this
would only affect the final MS in a list.
After the fix, the example posted to the ticket passes successfuly, with
all tested parallel breadths yielding the same result.- casatools/src/code/synthesis/TransformMachines2/BriggsCubeWeightor.cc (version 6bf9a287644247a534350fc7b2eaa493d427eb54) (diffs)
- casatools/src/code/synthesis/TransformMachines2/FTMachine.cc (version 6bf9a287644247a534350fc7b2eaa493d427eb54) (diffs)
- casatools/src/code/synthesis/TransformMachines2/FTMachine.h (version 6bf9a287644247a534350fc7b2eaa493d427eb54) (diffs)
-
Pedro Salas 760ee9575b2922443c4e3802223413ade1bbeffa m
Pull request #1082: CAS-14827
Merge in CASA/casa6 from CAS-14827 to master
* commit '99f29fadda56594587147f008f75f9141967250e':
Fix for CAS-14827 -
Kumar Golap 4f88fdbd9e1ab489ad918ac6f0f5e5a6a236a474 m
Pull request #1080: CAS-14858
Merge in CASA/casa6 from CAS-14858 to master
* commit 'e5adecaebf86ea59e8d415c87d1f975774a02e8f':
does not depend on default param of mosweight for awp2 test
The test value has changed with beam and sampling changes....fixed that in the test mvc with squint -
Pedro Salas <salas.mz@gmail.com> 99f29fadda56594587147f008f75f9141967250e m
Fix for CAS-14827
Removes assumption that the SENSITIVITY column in a GAIN_CURVE table
would allways have shape (2,N).
Adds a test based on the issue reported in CAS-14827. -
Kumar Golap e5adecaebf86ea59e8d415c87d1f975774a02e8f m
does not depend on default param of mosweight for awp2 test
-
Kumar Golap 71c68755dcea307d2f9f7fc449c4a7f98e045fa5 m
The test value has changed with beam and sampling changes....fixed that in the test mvc with squint