Coverage for /wheeldirectory/casa-6.7.0-12-py3.10.el8/lib/py/lib/python3.10/site-packages/casatasks/private/task_phaseshift.py: 6%

100 statements  

« prev     ^ index     » next       coverage.py v7.6.4, created at 2024-10-31 17:39 +0000

1 

2 

3from .mstools import write_history 

4from casatools import table, ms, mstransformer 

5from casatools import measures as me 

6from casatasks import casalog 

7from .parallel.parallel_data_helper import ParallelDataHelper 

8 

9 

10def phaseshift( 

11 vis=None, outputvis=None, keepmms=None, field=None, 

12 spw=None, scan=None, intent=None, array=None, 

13 observation=None, datacolumn=None, phasecenter=None 

14): 

15 """ 

16 Changes the phase center for either short or large 

17 offsets/angles w.r.t. the original 

18 """ 

19 casalog.origin('phaseshift') 

20 

21 if len(phasecenter) == 0: 

22 raise ValueError('phasecenter parameter must be specified') 

23 # Initiate the helper class 

24 pdh = ParallelDataHelper("phaseshift", locals()) 

25 

26 # Validate input and output parameters 

27 try: 

28 pdh.setupIO() 

29 except Exception as instance: 

30 casalog.post(str(instance), 'ERROR') 

31 raise RuntimeError(str(instance)) 

32 

33 # Input vis is an MMS 

34 if pdh.isMMSAndNotServer(vis) and keepmms: 

35 if not pdh.validateInputParams(): 

36 raise RuntimeError('Unable to continue with MMS processing') 

37 

38 pdh.setupCluster('phaseshift') 

39 

40 # Execute the jobs 

41 try: 

42 pdh.go() 

43 except Exception as instance: 

44 casalog.post(str(instance), 'ERROR') 

45 raise RuntimeError(str(instance)) 

46 return 

47 

48 # Create local copies of tools (has to be here, otherwise 

49 # ParallelDataHelper has a porblem digest the locals 

50 

51 tblocal = table() 

52 mslocal = ms() 

53 mtlocal = mstransformer() 

54 melocal = me() 

55 

56 # Actual task code starts here 

57 try: 

58 dirstr = phasecenter.split(' ') 

59 if not melocal.direction(dirstr[0], dirstr[1], dirstr[2]): 

60 raise ValueError("Illegal phacecenter specification " + phasecenter) 

61 try: 

62 # Gather all the parameters in a dictionary. 

63 config = {} 

64 

65 config = pdh.setupParameters( 

66 inputms=vis, outputms=outputvis, field=field, 

67 spw=spw, array=array, scan=scan, intent=intent, 

68 observation=observation 

69 ) 

70 

71 # Check if CORRECTED column exists, when requested 

72 datacolumn = datacolumn.upper() 

73 if datacolumn == 'CORRECTED': 

74 tblocal.open(vis) 

75 if 'CORRECTED_DATA' not in tblocal.colnames(): 

76 casalog.post( 

77 'Input CORRECTED_DATA does not exist. Will use DATA', 

78 'WARN' 

79 ) 

80 datacolumn = 'DATA' 

81 tblocal.close() 

82 

83 casalog.post('Will use datacolumn = ' + datacolumn, 'DEBUG') 

84 config['datacolumn'] = datacolumn 

85 

86 # Call MSTransform framework with tviphaseshift=True 

87 config['tviphaseshift'] = True 

88 tviphaseshift_config = {} 

89 tviphaseshift_config['phasecenter'] = phasecenter 

90 config['tviphaseshiftlib'] = dict(tviphaseshift_config) 

91 

92 # Configure the tool 

93 casalog.post(str(config), 'DEBUG1') 

94 mtlocal.config(config) 

95 

96 # Open the MS, select the data and configure the output 

97 mtlocal.open() 

98 

99 # Run the tool 

100 casalog.post('Shift phase center') 

101 mtlocal.run() 

102 

103 mtlocal.done() 

104 

105 except Exception as instance: 

106 mtlocal.done() 

107 casalog.post(str(instance), 'ERROR') 

108 raise RuntimeError(str(instance)) 

109 

110 # Write history to output MS, not the input ms. 

111 try: 

112 param_names = phaseshift.__code__.co_varnames[ 

113 :phaseshift.__code__.co_argcount 

114 ] 

115 vars = locals() 

116 param_vals = [vars[p] for p in param_names] 

117 

118 casalog.post('Updating the history in the output', 'DEBUG1') 

119 write_history( 

120 mslocal, outputvis, 'phaseshift', param_names, 

121 param_vals, casalog 

122 ) 

123 except Exception as instance: 

124 casalog.post( 

125 "*** Error " + str(instance) 

126 + " updating HISTORY", 'WARN' 

127 ) 

128 raise RuntimeError(str(instance)) 

129 

130 # Update field table 

131 try: 

132 

133 # Parse phase center string to obtain ra/dec 

134 dirstr = phasecenter.split(' ') 

135 try: 

136 thedir = melocal.direction(dirstr[0], dirstr[1], dirstr[2]) 

137 if (dirstr[0] != 'J2000'): 

138 # Convert to J2000 

139 thedir = melocal.measure(thedir, 'J2000') 

140 thenewra_rad = thedir['m0']['value'] 

141 thenewdec_rad = thedir['m1']['value'] 

142 except Exception as instance: 

143 casalog.post( 

144 "*** Error " + str(instance) 

145 + " when interpreting parameter \'phasecenter\': ", 

146 'SEVERE' 

147 ) 

148 raise RuntimeError(str(instance)) 

149 

150 # modify FIELD table 

151 tblocal.open(outputvis + '/FIELD', nomodify=False) 

152 pcol = tblocal.getcol('PHASE_DIR') 

153 for row in range(0, tblocal.nrows()): 

154 pcol[0][0][row] = thenewra_rad 

155 pcol[1][0][row] = thenewdec_rad 

156 tblocal.putcol('PHASE_DIR', pcol) 

157 except Exception as instance: 

158 casalog.post( 

159 "*** Error \'%s\' updating FIELD" + str(instance), 'WARN' 

160 ) 

161 raise RuntimeError(str(instance)) 

162 

163 finally: 

164 if tblocal: 

165 tblocal.done() 

166 tblocal = None 

167 if mslocal: 

168 mslocal.done() 

169 mslocal = None 

170 if mtlocal: 

171 mtlocal.done() 

172 mtlocal = None 

173 if melocal: 

174 melocal.done() 

175 melocal = None 

176