Build: #19 failed
Job: Test Tools MPI Many Linux 2.28 Rocky 8.10 Py3.10 failed
su adivsechansel getfreqrange: Test case result
The below summarizes the result of the test " su adivsechansel getfreqrange" in build 19 of CASA - CMake MPI - Test Tools MPI Many Linux 2.28 Rocky 8.10 Py3.10.
- Description
- su adivsechansel getfreqrange
- Test class
- tests.tools.synthesisutils.test_tool_synthesisutils.advisechansel_test
- Method
- test_su_adivsechansel_getfreqrange
- Duration
- < 1 sec
- Status
- Failed (Existing Failure)
Error Log
KeyError: 'freqstart'
self = <test_tool_synthesisutils.advisechansel_test testMethod=test_su_adivsechansel_getfreqrange>
def test_su_adivsechansel_getfreqrange(self):
'''Test that frequency range for given data selections is returned correctly'''
refdict = {'freqend': {'unit': 'Hz', 'value': 358203002929.7875}, 'freqstart': {'unit': 'Hz', 'value': 356558910156.25}}
su = synthesisutils()
inputms ='twhya.short.ms'
res = su.advisechansel(freqframe='TOPO', getfreqrange=True,spwselection='0:500~3839,1',fieldid=2, msname=inputms)
(pof, errmsg) = self.checkdict(res, refdict, 'TOPO test')
#fstlsrk= '356.58364232412697GHz' fenlsrk= '358.22772677745405GHz'
# corresponding LSRK frequencies
reslsrk = su.advisechansel(freqframe='LSRK', getfreqrange=True,spwselection='0:500~3839,1', fieldid=2, msname=inputms)
del su
reflsrkdict = {'freqend': {'unit': 'Hz', 'value': 358227726777.45405}, 'freqstart': {'unit': 'Hz', 'value': 356583642324.12697}}
> diff_freqstart = reslsrk['freqstart']['value']-reflsrkdict['freqstart']['value']
E KeyError: 'freqstart'
../../../casatools/tests/tools/synthesisutils/test_tool_synthesisutils.py:457: KeyError