2024-09-13 22:30:57 INFO ::casa Using user configuration file /home/casatest/.casa/config.py 2024-09-13 22:30:57 INFO ::casa loaded config file : /wheeldirectory/casa-CAS-14370-1-py3.8.el8/lib/py/lib/python3.8/site-packages/casaconfig/config.py 2024-09-13 22:30:57 INFO ::casa loaded config file : /home/casatest/.casa/config.py 2024-09-13 22:30:57 INFO ::casa 2024-09-13 22:30:57 INFO ::casa config values 2024-09-13 22:30:57 INFO ::casa agg = False 2024-09-13 22:30:57 INFO ::casa cachedir = '/home/casatest/.casa' 2024-09-13 22:30:57 INFO ::casa casaconfig_verbose = 1 2024-09-13 22:30:57 INFO ::casa colors = 'Neutral' 2024-09-13 22:30:57 INFO ::casa data_auto_update = False 2024-09-13 22:30:57 INFO ::casa datapath = ['/opt/casa/data/master', '/opt/casa/data/casatestdata'] 2024-09-13 22:30:57 INFO ::casa iplog = False 2024-09-13 22:30:57 INFO ::casa iplogfile = '/home/casatest/casa6/casatasks/tests/casashell_tests/work/test_task_initweights_casashell/ipython-20240913-223055.log' 2024-09-13 22:30:57 INFO ::casa log2term = True 2024-09-13 22:30:57 INFO ::casa logfile = '/home/casatest/casa6/casatasks/tests/casashell_tests/work/test_task_initweights_casashell/casa-20240913-223055.log' 2024-09-13 22:30:57 INFO ::casa measures_auto_update = False 2024-09-13 22:30:57 INFO ::casa measurespath = '/opt/casa/data/master' 2024-09-13 22:30:57 INFO ::casa nogui = False 2024-09-13 22:30:57 INFO ::casa nologfile = False 2024-09-13 22:30:57 INFO ::casa nologger = True 2024-09-13 22:30:57 INFO ::casa pipeline = False 2024-09-13 22:30:57 INFO ::casa startupfile = '/home/casatest/.casa/startup.py' 2024-09-13 22:30:57 INFO ::casa user_site = False 2024-09-13 22:30:57 INFO ::casa 2024-09-13 22:30:57 INFO ::casa casarundata version is unknown, this is probably a legacy version not installed by casaconfig 2024-09-13 22:30:57 INFO ::casa measures version is unknown, this is probably a legacy version not installed by casaconfig 2024-09-13 22:30:57 INFO ::casa 2024-09-13 22:30:57 INFO ::casa Checking Measures tables in data repository sub-directory /opt/casa/data/master/geodetic 2024-09-13 22:30:57 INFO ::casa IERSeop2000 (version date, last date in table (UTC)): 2024/08/31/15:00, 2024/08/01/00:00:00 2024-09-13 22:30:57 INFO ::casa IERSeop97 (version date, last date in table (UTC)): 2024/08/31/15:00, 2024/08/01/00:00:00 2024-09-13 22:30:57 INFO ::casa IERSpredict (version date, last date in table (UTC)): 2024/09/13/15:00, 2024/12/12/00:00:00 2024-09-13 22:30:57 INFO ::casa TAI_UTC (version date, last date in table (UTC)): 2024/08/28/15:00, 2017/01/01/00:00:00 2024-09-13 22:30:59 INFO initweights::::casa ########################################## 2024-09-13 22:30:59 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:30:59 INFO initweights::::casa initweights( vis='weight_inconsistent.ms', wtmode='nyq', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='', spwmap=[], dowtsp=False ) 2024-09-13 22:30:59 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:30:59 INFO initweights::calibrater::open Opening MS: weight_inconsistent.ms for calibration. 2024-09-13 22:30:59 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:30:59 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:30:59 INFO initweights::Calibrater::initWeights Initializing SIGMA and WEIGHT according to channel bandwidth and integration time. 2024-09-13 22:30:59 INFO initweights::Calibrater::initWeights Removing SIGMA_SPECTRUM for non-channelized weight. 2024-09-13 22:30:59 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:30:59 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:30:58.601304 End time: 2024-09-13 22:30:58.677499 2024-09-13 22:30:59 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:30:59 INFO initweights::::casa ########################################## 2024-09-13 22:30:59 INFO initweights::::casa ########################################## 2024-09-13 22:30:59 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:30:59 INFO initweights::::casa initweights( vis='weight_inconsistent.ms', wtmode='nyq', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='', spwmap=[], dowtsp=True ) 2024-09-13 22:30:59 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:30:59 INFO initweights::calibrater::open Opening MS: weight_inconsistent.ms for calibration. 2024-09-13 22:30:59 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:30:59 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:30:59 INFO initweights::Calibrater::initWeights Initializing SIGMA and WEIGHT according to channel bandwidth and integration time. 2024-09-13 22:30:59 INFO initweights::Calibrater::initWeights Removing SIGMA_SPECTRUM for non-channelized weight. 2024-09-13 22:30:59 INFO initweights::Calibrater::initWeights Creating WEIGHT_SPECTRUM. 2024-09-13 22:30:59 INFO initweights::Calibrater::initWeights Initializing WEIGHT_SPECTRUM uniformly in channel (==WEIGHT). 2024-09-13 22:30:59 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:30:59 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:30:58.990608 End time: 2024-09-13 22:30:59.152986 2024-09-13 22:30:59 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:30:59 INFO initweights::::casa ########################################## 2024-09-13 22:31:00 INFO initweights::::casa ########################################## 2024-09-13 22:31:00 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:00 INFO initweights::::casa initweights( vis='weight_inconsistent.ms', wtmode='ones', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='', spwmap=[], dowtsp=False ) 2024-09-13 22:31:00 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:00 INFO initweights::calibrater::open Opening MS: weight_inconsistent.ms for calibration. 2024-09-13 22:31:00 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:00 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:00 INFO initweights::Calibrater::initWeights Initializing SIGMA and WEIGHT with 1.0 2024-09-13 22:31:00 INFO initweights::Calibrater::initWeights Removing SIGMA_SPECTRUM for non-channelized weight. 2024-09-13 22:31:00 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:00 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:30:59.588299 End time: 2024-09-13 22:30:59.658854 2024-09-13 22:31:00 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:00 INFO initweights::::casa ########################################## 2024-09-13 22:31:00 INFO initweights::::casa ########################################## 2024-09-13 22:31:00 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:00 INFO initweights::::casa initweights( vis='weight_inconsistent.ms', wtmode='ones', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='', spwmap=[], dowtsp=True ) 2024-09-13 22:31:00 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:00 INFO initweights::calibrater::open Opening MS: weight_inconsistent.ms for calibration. 2024-09-13 22:31:00 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:00 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:00 INFO initweights::Calibrater::initWeights Initializing SIGMA and WEIGHT with 1.0 2024-09-13 22:31:00 INFO initweights::Calibrater::initWeights Removing SIGMA_SPECTRUM for non-channelized weight. 2024-09-13 22:31:00 INFO initweights::Calibrater::initWeights Creating WEIGHT_SPECTRUM. 2024-09-13 22:31:00 INFO initweights::Calibrater::initWeights Initializing WEIGHT_SPECTRUM uniformly in channel (==WEIGHT). 2024-09-13 22:31:00 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:00 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:30:59.979183 End time: 2024-09-13 22:31:00.096992 2024-09-13 22:31:00 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:00 INFO initweights::::casa ########################################## 2024-09-13 22:31:00 INFO initweights::::casa ########################################## 2024-09-13 22:31:00 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:00 INFO initweights::::casa initweights( vis='weight_inconsistent.ms', wtmode='sigma', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='', spwmap=[], dowtsp=False ) 2024-09-13 22:31:00 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:00 INFO initweights::calibrater::open Opening MS: weight_inconsistent.ms for calibration. 2024-09-13 22:31:00 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:00 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:00 INFO initweights::Calibrater::initWeights Initializing WEIGHT according to existing SIGMA. 2024-09-13 22:31:00 INFO initweights::Calibrater::initWeights Removing SIGMA_SPECTRUM for non-channelized weight. 2024-09-13 22:31:01 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:01 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:00.487124 End time: 2024-09-13 22:31:00.537906 2024-09-13 22:31:01 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:01 INFO initweights::::casa ########################################## 2024-09-13 22:31:01 INFO initweights::::casa ########################################## 2024-09-13 22:31:01 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:01 INFO initweights::::casa initweights( vis='weight_inconsistent.ms', wtmode='sigma', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='', spwmap=[], dowtsp=True ) 2024-09-13 22:31:01 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:01 INFO initweights::calibrater::open Opening MS: weight_inconsistent.ms for calibration. 2024-09-13 22:31:01 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:01 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:01 INFO initweights::Calibrater::initWeights Initializing WEIGHT according to existing SIGMA. 2024-09-13 22:31:01 INFO initweights::Calibrater::initWeights Removing SIGMA_SPECTRUM for non-channelized weight. 2024-09-13 22:31:01 INFO initweights::Calibrater::initWeights Creating WEIGHT_SPECTRUM. 2024-09-13 22:31:01 INFO initweights::Calibrater::initWeights Initializing WEIGHT_SPECTRUM uniformly in channel (==WEIGHT). 2024-09-13 22:31:01 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:01 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:00.894457 End time: 2024-09-13 22:31:01.041580 2024-09-13 22:31:01 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:01 INFO initweights::::casa ########################################## 2024-09-13 22:31:01 INFO initweights::::casa ########################################## 2024-09-13 22:31:01 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:01 INFO initweights::::casa initweights( vis='weight_inconsistent.ms', wtmode='weight', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='', spwmap=[], dowtsp=True ) 2024-09-13 22:31:01 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:01 INFO initweights::calibrater::open Opening MS: weight_inconsistent.ms for calibration. 2024-09-13 22:31:01 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:01 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:01 INFO initweights::Calibrater::initWeights Removing SIGMA_SPECTRUM for non-channelized weight. 2024-09-13 22:31:01 INFO initweights::Calibrater::initWeights Creating WEIGHT_SPECTRUM. 2024-09-13 22:31:01 INFO initweights::Calibrater::initWeights Initializing WEIGHT_SPECTRUM uniformly in channel (==WEIGHT). 2024-09-13 22:31:02 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:02 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:01.444149 End time: 2024-09-13 22:31:01.556749 2024-09-13 22:31:02 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:02 INFO initweights::::casa ########################################## 2024-09-13 22:31:03 INFO initweights::::casa ########################################## 2024-09-13 22:31:03 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:03 INFO initweights::::casa initweights( vis='weight_speccols.ms', wtmode='delsigsp', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='', spwmap=[], dowtsp=False ) 2024-09-13 22:31:03 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:03 INFO initweights::calibrater::open Opening MS: weight_speccols.ms for calibration. 2024-09-13 22:31:03 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:03 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:03 INFO initweights::Calibrater::initWeights Removing SIGMA_SPECTRUM. 2024-09-13 22:31:03 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:03 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:03.034607 End time: 2024-09-13 22:31:03.072336 2024-09-13 22:31:03 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:03 INFO initweights::::casa ########################################## 2024-09-13 22:31:03 INFO initweights::::casa ########################################## 2024-09-13 22:31:03 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:03 INFO initweights::::casa initweights( vis='weight_speccols.ms', wtmode='delsigsp', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='', spwmap=[], dowtsp=True ) 2024-09-13 22:31:03 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:03 INFO initweights::calibrater::open Opening MS: weight_speccols.ms for calibration. 2024-09-13 22:31:03 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:03 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:03 INFO initweights::Calibrater::initWeights Removing SIGMA_SPECTRUM. 2024-09-13 22:31:03 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:03 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:03.454917 End time: 2024-09-13 22:31:03.495841 2024-09-13 22:31:03 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:03 INFO initweights::::casa ########################################## 2024-09-13 22:31:04 INFO initweights::::casa ########################################## 2024-09-13 22:31:04 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:04 INFO initweights::::casa initweights( vis='weight_speccols.ms', wtmode='delwtsp', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='', spwmap=[], dowtsp=False ) 2024-09-13 22:31:04 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:04 INFO initweights::calibrater::open Opening MS: weight_speccols.ms for calibration. 2024-09-13 22:31:04 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:04 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:04 INFO initweights::Calibrater::initWeights Removing WEIGHT_SPECTRUM. 2024-09-13 22:31:04 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:04 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:03.868057 End time: 2024-09-13 22:31:03.912189 2024-09-13 22:31:04 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:04 INFO initweights::::casa ########################################## 2024-09-13 22:31:04 INFO initweights::::casa ########################################## 2024-09-13 22:31:04 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:04 INFO initweights::::casa initweights( vis='weight_speccols.ms', wtmode='delwtsp', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='', spwmap=[], dowtsp=True ) 2024-09-13 22:31:04 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:04 INFO initweights::calibrater::open Opening MS: weight_speccols.ms for calibration. 2024-09-13 22:31:04 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:04 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:04 INFO initweights::Calibrater::initWeights Removing WEIGHT_SPECTRUM. 2024-09-13 22:31:04 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:04 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:04.269959 End time: 2024-09-13 22:31:04.306478 2024-09-13 22:31:04 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:04 INFO initweights::::casa ########################################## 2024-09-13 22:31:05 INFO initweights::::casa ########################################## 2024-09-13 22:31:05 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:05 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tinttsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='nearest,nearest', spwmap=[], dowtsp=False ) 2024-09-13 22:31:05 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:05 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:05 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:05 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:05 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:05 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:05 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:05 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 9 10 11 12 13 14 15 16 2024-09-13 22:31:05 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=nearest,nearest spwmap=[-1] calWt=true 2024-09-13 22:31:05 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth, integration time, and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:05 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:05 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:05.096997 End time: 2024-09-13 22:31:05.233435 2024-09-13 22:31:05 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:05 INFO initweights::::casa ########################################## 2024-09-13 22:31:05 INFO initweights::::casa ########################################## 2024-09-13 22:31:05 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:05 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tinttsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='nearest,nearest', spwmap=[], dowtsp=True ) 2024-09-13 22:31:05 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:05 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:05 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:05 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:05 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:05 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:05 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:05 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 9 10 11 12 13 14 15 16 2024-09-13 22:31:05 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=nearest,nearest spwmap=[-1] calWt=true 2024-09-13 22:31:05 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth, integration time, and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:05 INFO initweights::Calibrater::selectvis Creating WEIGHT_SPECTRUM. 2024-09-13 22:31:06 INFO initweights::Calibrater::selectvis Creating SIGMA_SPECTRUM. 2024-09-13 22:31:06 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:06 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:05.453626 End time: 2024-09-13 22:31:05.707830 2024-09-13 22:31:06 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:06 INFO initweights::::casa ########################################## 2024-09-13 22:31:06 INFO initweights::::casa ########################################## 2024-09-13 22:31:06 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:06 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tinttsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='nearest,nearest', spwmap=[], dowtsp=False ) 2024-09-13 22:31:06 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:06 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:06 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:06 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:06 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:06 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:06 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:06 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 9 10 11 12 13 14 15 16 2024-09-13 22:31:06 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=nearest,nearest spwmap=[-1] calWt=true 2024-09-13 22:31:06 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth, integration time, and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:06 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:06 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:06.105716 End time: 2024-09-13 22:31:06.204431 2024-09-13 22:31:06 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:06 INFO initweights::::casa ########################################## 2024-09-13 22:31:06 INFO initweights::::casa ########################################## 2024-09-13 22:31:06 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:06 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tinttsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='nearest,nearest', spwmap=[], dowtsp=True ) 2024-09-13 22:31:06 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:06 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:06 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:06 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:06 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:06 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:06 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:06 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 9 10 11 12 13 14 15 16 2024-09-13 22:31:06 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=nearest,nearest spwmap=[-1] calWt=true 2024-09-13 22:31:06 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth, integration time, and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:06 INFO initweights::Calibrater::selectvis Creating WEIGHT_SPECTRUM. 2024-09-13 22:31:06 INFO initweights::Calibrater::selectvis Creating SIGMA_SPECTRUM. 2024-09-13 22:31:06 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:07 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:06.337540 End time: 2024-09-13 22:31:06.606337 2024-09-13 22:31:07 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:07 INFO initweights::::casa ########################################## 2024-09-13 22:31:07 INFO initweights::::casa ########################################## 2024-09-13 22:31:07 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:07 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tinttsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='nearest,nearest', spwmap=[], dowtsp=False ) 2024-09-13 22:31:07 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:07 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:07 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:07 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:07 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:07 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:07 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:07 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 9 10 11 12 13 14 15 16 2024-09-13 22:31:07 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=nearest,nearest spwmap=[-1] calWt=true 2024-09-13 22:31:07 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth, integration time, and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:07 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:07 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:07.092619 End time: 2024-09-13 22:31:07.184371 2024-09-13 22:31:07 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:07 INFO initweights::::casa ########################################## 2024-09-13 22:31:07 INFO initweights::::casa ########################################## 2024-09-13 22:31:07 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:07 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tinttsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='nearest,nearest', spwmap=[], dowtsp=True ) 2024-09-13 22:31:07 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:07 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:07 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:07 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:07 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:07 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:07 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:07 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 9 10 11 12 13 14 15 16 2024-09-13 22:31:07 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=nearest,nearest spwmap=[-1] calWt=true 2024-09-13 22:31:07 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth, integration time, and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:07 INFO initweights::Calibrater::selectvis Creating WEIGHT_SPECTRUM. 2024-09-13 22:31:07 INFO initweights::Calibrater::selectvis Creating SIGMA_SPECTRUM. 2024-09-13 22:31:07 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:08 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:07.310822 End time: 2024-09-13 22:31:07.519159 2024-09-13 22:31:08 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:08 INFO initweights::::casa ########################################## 2024-09-13 22:31:08 INFO initweights::::casa ########################################## 2024-09-13 22:31:08 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:08 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='linear,cspline', spwmap=[], dowtsp=False ) 2024-09-13 22:31:08 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:08 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:08 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:08 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:08 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:08 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:08 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:08 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 9 10 11 12 13 14 15 16 2024-09-13 22:31:08 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=linear,cspline spwmap=[-1] calWt=true 2024-09-13 22:31:08 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:08 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:08 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:07.907749 End time: 2024-09-13 22:31:08.003223 2024-09-13 22:31:08 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:08 INFO initweights::::casa ########################################## 2024-09-13 22:31:08 INFO initweights::::casa ########################################## 2024-09-13 22:31:08 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:08 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='linear,cspline', spwmap=[], dowtsp=True ) 2024-09-13 22:31:08 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:08 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:08 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:08 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:08 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:08 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:08 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:08 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 9 10 11 12 13 14 15 16 2024-09-13 22:31:08 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=linear,cspline spwmap=[-1] calWt=true 2024-09-13 22:31:08 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:08 INFO initweights::Calibrater::selectvis Creating WEIGHT_SPECTRUM. 2024-09-13 22:31:08 INFO initweights::Calibrater::selectvis Creating SIGMA_SPECTRUM. 2024-09-13 22:31:08 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:08 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:08.124203 End time: 2024-09-13 22:31:08.318455 2024-09-13 22:31:08 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:08 INFO initweights::::casa ########################################## 2024-09-13 22:31:09 INFO initweights::::casa ########################################## 2024-09-13 22:31:09 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:09 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='linear,linear', spwmap=[], dowtsp=False ) 2024-09-13 22:31:09 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:09 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:09 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:09 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:09 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:09 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:09 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:09 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 9 10 11 12 13 14 15 16 2024-09-13 22:31:09 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=linear,linear spwmap=[-1] calWt=true 2024-09-13 22:31:09 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:09 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:09 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:08.703501 End time: 2024-09-13 22:31:08.794262 2024-09-13 22:31:09 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:09 INFO initweights::::casa ########################################## 2024-09-13 22:31:09 INFO initweights::::casa ########################################## 2024-09-13 22:31:09 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:09 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='linear,linear', spwmap=[], dowtsp=True ) 2024-09-13 22:31:09 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:09 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:09 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:09 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:09 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:09 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:09 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:09 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 9 10 11 12 13 14 15 16 2024-09-13 22:31:09 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=linear,linear spwmap=[-1] calWt=true 2024-09-13 22:31:09 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:09 INFO initweights::Calibrater::selectvis Creating WEIGHT_SPECTRUM. 2024-09-13 22:31:09 INFO initweights::Calibrater::selectvis Creating SIGMA_SPECTRUM. 2024-09-13 22:31:09 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:09 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:08.911325 End time: 2024-09-13 22:31:09.108255 2024-09-13 22:31:09 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:09 INFO initweights::::casa ########################################## 2024-09-13 22:31:09 INFO initweights::::casa ########################################## 2024-09-13 22:31:09 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:09 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='nearest,nearest', spwmap=[], dowtsp=False ) 2024-09-13 22:31:09 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:09 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:10 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:10 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:10 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:10 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:10 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:10 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 9 10 11 12 13 14 15 16 2024-09-13 22:31:10 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=nearest,nearest spwmap=[-1] calWt=true 2024-09-13 22:31:10 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:10 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:10 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:09.492375 End time: 2024-09-13 22:31:09.599185 2024-09-13 22:31:10 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:10 INFO initweights::::casa ########################################## 2024-09-13 22:31:10 INFO initweights::::casa ########################################## 2024-09-13 22:31:10 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:10 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='nearest,nearest', spwmap=[], dowtsp=True ) 2024-09-13 22:31:10 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:10 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:10 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:10 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:10 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:10 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:10 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:10 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 9 10 11 12 13 14 15 16 2024-09-13 22:31:10 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=nearest,nearest spwmap=[-1] calWt=true 2024-09-13 22:31:10 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:10 INFO initweights::Calibrater::selectvis Creating WEIGHT_SPECTRUM. 2024-09-13 22:31:10 INFO initweights::Calibrater::selectvis Creating SIGMA_SPECTRUM. 2024-09-13 22:31:10 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:10 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:09.720922 End time: 2024-09-13 22:31:09.974355 2024-09-13 22:31:10 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:10 INFO initweights::::casa ########################################## 2024-09-13 22:31:10 INFO initweights::::casa ########################################## 2024-09-13 22:31:10 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:10 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tinttsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='linear,cspline', spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7], dowtsp=False ) 2024-09-13 22:31:10 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:10 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:10 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:10 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:10 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:10 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:10 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:10 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 10 12 14 16 2024-09-13 22:31:10 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=linear,cspline spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7] calWt=true 2024-09-13 22:31:10 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth, integration time, and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:10 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:10 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:10.369152 End time: 2024-09-13 22:31:10.474671 2024-09-13 22:31:10 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:10 INFO initweights::::casa ########################################## 2024-09-13 22:31:11 INFO initweights::::casa ########################################## 2024-09-13 22:31:11 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:11 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tinttsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='linear,cspline', spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7], dowtsp=True ) 2024-09-13 22:31:11 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:11 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:11 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:11 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:11 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:11 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:11 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:11 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 10 12 14 16 2024-09-13 22:31:11 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=linear,cspline spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7] calWt=true 2024-09-13 22:31:11 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth, integration time, and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:11 INFO initweights::Calibrater::selectvis Creating WEIGHT_SPECTRUM. 2024-09-13 22:31:11 INFO initweights::Calibrater::selectvis Creating SIGMA_SPECTRUM. 2024-09-13 22:31:11 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:11 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:10.611816 End time: 2024-09-13 22:31:10.855920 2024-09-13 22:31:11 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:11 INFO initweights::::casa ########################################## 2024-09-13 22:31:11 INFO initweights::::casa ########################################## 2024-09-13 22:31:11 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:11 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tinttsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='linear,linear', spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7], dowtsp=False ) 2024-09-13 22:31:11 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:11 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:11 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:11 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:11 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:11 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:11 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:11 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 10 12 14 16 2024-09-13 22:31:11 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=linear,linear spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7] calWt=true 2024-09-13 22:31:11 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth, integration time, and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:11 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:11 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:11.296746 End time: 2024-09-13 22:31:11.400764 2024-09-13 22:31:11 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:11 INFO initweights::::casa ########################################## 2024-09-13 22:31:12 INFO initweights::::casa ########################################## 2024-09-13 22:31:12 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:12 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tinttsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='linear,linear', spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7], dowtsp=True ) 2024-09-13 22:31:12 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:12 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:12 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:12 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:12 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:12 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:12 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:12 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 10 12 14 16 2024-09-13 22:31:12 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=linear,linear spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7] calWt=true 2024-09-13 22:31:12 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth, integration time, and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:12 INFO initweights::Calibrater::selectvis Creating WEIGHT_SPECTRUM. 2024-09-13 22:31:12 INFO initweights::Calibrater::selectvis Creating SIGMA_SPECTRUM. 2024-09-13 22:31:12 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:12 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:11.514087 End time: 2024-09-13 22:31:11.808705 2024-09-13 22:31:12 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:12 INFO initweights::::casa ########################################## 2024-09-13 22:31:12 INFO initweights::::casa ########################################## 2024-09-13 22:31:12 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:12 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tinttsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='nearest,nearest', spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7], dowtsp=False ) 2024-09-13 22:31:12 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:12 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:12 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:12 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:12 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:12 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:12 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:12 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 10 12 14 16 2024-09-13 22:31:12 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=nearest,nearest spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7] calWt=true 2024-09-13 22:31:12 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth, integration time, and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:12 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:12 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:12.029215 End time: 2024-09-13 22:31:12.137349 2024-09-13 22:31:12 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:12 INFO initweights::::casa ########################################## 2024-09-13 22:31:12 INFO initweights::::casa ########################################## 2024-09-13 22:31:12 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:12 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tinttsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='nearest,nearest', spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7], dowtsp=True ) 2024-09-13 22:31:12 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:12 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:12 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:12 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:12 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:12 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:12 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:12 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 10 12 14 16 2024-09-13 22:31:12 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=nearest,nearest spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7] calWt=true 2024-09-13 22:31:12 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth, integration time, and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:12 INFO initweights::Calibrater::selectvis Creating WEIGHT_SPECTRUM. 2024-09-13 22:31:12 INFO initweights::Calibrater::selectvis Creating SIGMA_SPECTRUM. 2024-09-13 22:31:12 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:12 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:12.226163 End time: 2024-09-13 22:31:12.461526 2024-09-13 22:31:12 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:12 INFO initweights::::casa ########################################## 2024-09-13 22:31:13 INFO initweights::::casa ########################################## 2024-09-13 22:31:13 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:13 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='linear,cspline', spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7], dowtsp=False ) 2024-09-13 22:31:13 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:13 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:13 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:13 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:13 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:13 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:13 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:13 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 10 12 14 16 2024-09-13 22:31:13 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=linear,cspline spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7] calWt=true 2024-09-13 22:31:13 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:13 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:13 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:12.745395 End time: 2024-09-13 22:31:12.849222 2024-09-13 22:31:13 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:13 INFO initweights::::casa ########################################## 2024-09-13 22:31:13 INFO initweights::::casa ########################################## 2024-09-13 22:31:13 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:13 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='linear,cspline', spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7], dowtsp=True ) 2024-09-13 22:31:13 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:13 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:13 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:13 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:13 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:13 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:13 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:13 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 10 12 14 16 2024-09-13 22:31:13 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=linear,cspline spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7] calWt=true 2024-09-13 22:31:13 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:13 INFO initweights::Calibrater::selectvis Creating WEIGHT_SPECTRUM. 2024-09-13 22:31:13 INFO initweights::Calibrater::selectvis Creating SIGMA_SPECTRUM. 2024-09-13 22:31:13 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:13 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:13.028568 End time: 2024-09-13 22:31:13.265420 2024-09-13 22:31:13 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:13 INFO initweights::::casa ########################################## 2024-09-13 22:31:14 INFO initweights::::casa ########################################## 2024-09-13 22:31:14 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:14 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='linear,linear', spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7], dowtsp=False ) 2024-09-13 22:31:14 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:14 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:14 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:14 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:14 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:14 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:14 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:14 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 10 12 14 16 2024-09-13 22:31:14 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=linear,linear spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7] calWt=true 2024-09-13 22:31:14 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:14 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:14 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:13.537398 End time: 2024-09-13 22:31:13.686870 2024-09-13 22:31:14 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:14 INFO initweights::::casa ########################################## 2024-09-13 22:31:14 INFO initweights::::casa ########################################## 2024-09-13 22:31:14 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:14 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='linear,linear', spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7], dowtsp=True ) 2024-09-13 22:31:14 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:14 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:14 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:14 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:14 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:14 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:14 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:14 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 10 12 14 16 2024-09-13 22:31:14 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=linear,linear spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7] calWt=true 2024-09-13 22:31:14 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:14 INFO initweights::Calibrater::selectvis Creating WEIGHT_SPECTRUM. 2024-09-13 22:31:14 INFO initweights::Calibrater::selectvis Creating SIGMA_SPECTRUM. 2024-09-13 22:31:14 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:14 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:13.800782 End time: 2024-09-13 22:31:14.039230 2024-09-13 22:31:14 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:14 INFO initweights::::casa ########################################## 2024-09-13 22:31:14 INFO initweights::::casa ########################################## 2024-09-13 22:31:14 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:14 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='nearest,nearest', spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7], dowtsp=False ) 2024-09-13 22:31:14 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:14 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:14 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:14 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:14 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:14 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:14 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:14 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 10 12 14 16 2024-09-13 22:31:14 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=nearest,nearest spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7] calWt=true 2024-09-13 22:31:14 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:14 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:14 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:14.353560 End time: 2024-09-13 22:31:14.456752 2024-09-13 22:31:14 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:14 INFO initweights::::casa ########################################## 2024-09-13 22:31:15 INFO initweights::::casa ########################################## 2024-09-13 22:31:15 INFO initweights::::casa ##### Begin Task: initweights ##### 2024-09-13 22:31:15 INFO initweights::::casa initweights( vis='tsysweight_ave.ms', wtmode='tsys', tsystable='tsysweight_ave.tsys.cal', gainfield='', interp='nearest,nearest', spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7], dowtsp=True ) 2024-09-13 22:31:15 INFO initweights::calibrater::open ****Using NEW VI2-driven calibrater tool**** 2024-09-13 22:31:15 INFO initweights::calibrater::open Opening MS: tsysweight_ave.ms for calibration. 2024-09-13 22:31:15 INFO initweights::Calibrater:: Initializing nominal selection to the whole MS. 2024-09-13 22:31:15 INFO initweights::calibrater::initweights Beginning initweights--------------------------- 2024-09-13 22:31:15 INFO initweights::Calibrater::initWeightsWithTsys Weight initialization does not support selection. Resetting MS selection. 2024-09-13 22:31:15 INFO initweights::Calibrater::selectvis Performing selection on MeasurementSet 2024-09-13 22:31:15 INFO initweights::Calibrater::selectvis Selection did not drop any rows 2024-09-13 22:31:15 INFO initweights::Calibrater::selectvis Frequency selection: Selecting all channels in all spws. The following MS spws have no corresponding cal spws in tsysweight_ave.tsys.cal: 0 2 4 6 8 10 12 14 16 2024-09-13 22:31:15 INFO initweights::Calibrater::selectvis . B TSYS: table=tsysweight_ave.tsys.cal select= interp=nearest,nearest spwmap=[0, 1, 2, 3, 4, 5, 6, 7, 8, 1, 10, 3, 12, 5, 14, 7] calWt=true 2024-09-13 22:31:15 WARN initweights::Calibrater::selectvis Initializing SIGMA and WEIGHT according to channel bandwidth and Tsys. NOTE this is an expert mode. 2024-09-13 22:31:15 INFO initweights::Calibrater::selectvis Creating WEIGHT_SPECTRUM. 2024-09-13 22:31:15 INFO initweights::Calibrater::selectvis Creating SIGMA_SPECTRUM. 2024-09-13 22:31:15 INFO initweights::calibrater::initweights Finished initweights. 2024-09-13 22:31:15 INFO initweights::::casa Task initweights complete. Start time: 2024-09-13 22:31:14.555560 End time: 2024-09-13 22:31:14.845627 2024-09-13 22:31:15 INFO initweights::::casa ##### End Task: initweights ##### 2024-09-13 22:31:15 INFO initweights::::casa ########################################## Using user configuration file /home/casatest/.casa/config.py Using matplotlib backend: agg CASA 6.7.0.2a14370.dev1 -- Common Astronomy Software Applications [6.7.0.2a14370.dev1] initweights tests will use data from /opt/casa/data/casatestdata/unittest/initweights/ Running tests... ---------------------------------------------------------------------- ................................... ---------------------------------------------------------------------- Ran 35 tests in 17.674s OK Generating XML reports...